Digitale stroomtang | AC | 400A

  • Beschrijving
  • Specificaties
AC stroombereik: 4A, 40A, 400A
AC - DC Voltage: 600V
Weerstand: 40 Mohm
Ingangweerstand: 20 Mohm
Bekopening: 28mm
Diodetest, Doorbeltest, datahold, LCD backlight.
LCD afmeting: 25 x 37 mm
Afmeting: 215 x 63  x 36 mm

Product parameters:
- measurement of voltage, current and frequency of high voltage up to 600 V
- non-contact electric field sensing (NCV)
- temperature measurement -40°C to 1000°C
- multi-segment display and audible / visual alarm
- protection against voltages greater than 600V across ranges
- automatic range switching
- accuracy is guaranteed in the range of 1% to 100% of the range

Technical parameters:

1. AC current measurement (ranges / resolution / accuracy):

4,000A / 0.001A / 50Hz ~ 100Hz ± (4.0% +10)
40.00A / 0.010A / 50Hz ~ 100Hz ± (2.0% +10)
400.0A / 0.100A / 50Hz ~ 100Hz ± (2.0% +10)
- frequency monitoring accuracy when measuring AC current in the range of 50 to 100Hz is ± (1.0% + 5) at 0.1Hz resolution
- overload protection at 420A

2. AC voltage measurement (range / resolution / accuracy):

4.000V / 0.001V / 10Hz ~ 10kHz ± (1.0% +5)
40.00V / 0.010V / 10Hz ~ 10kHz ± (0.8% +5)
400.0V / 0.100V / 10Hz ~ 10kHz ± (0.8% +5)
600.0V / 1,000V / 10Hz ~ 10kHz ± (0.8% +5)
- frequency monitoring accuracy when measuring AC voltage in the range of 10Hz to 10kHz ± (1.0% + 5) at a resolution of 0.01Hz to 0.01kHz
- overload protection at 600Vrms
- input impedance approx. 10MGΩ

3. DC voltage measurement (range / resolution / accuracy):

400.0mV / 0.100mV / ± (0.7% +3)
4.000V / 0.001V / ± (0.5% +2)
40.00V / 0.010V / ± (0.7% +3)
400.0V / 0.100V / ± (0.7% +3)
600V / 1,000V / ± (0.7% +3)
- input impedance approx. 10MΩ
- overload protection at 600Vrms

4. Resistance measurement (ranges / resolution / accuracy):

400.0Ω / 0.1Ω / ± (1.0% +2)
4,000kΩ / 0.001kΩ / ± (0.8% +2)
40.00kΩ / 0.01kΩ / ± (0.8% +2)
400.0kΩ / 0.1kΩ / ± (0.8% +2)
4,000MΩ / 0.001MΩ / ± (2.0% +5)
40.00MΩ / 0.01MΩ / ± (2.0% +5)
- overload protection at 600 Vrms

5. Capacity measurement (ranges / resolution / accuracy):

4,000nF / 0.001nF / ± (4.0% +10)
40.00nF / 0.01nF / ± (4.0% +10)
400.0nF / 0.1knF / ± (4.0% +10)
4,000μF / 0.001μF / ± (4.0% +5)
40.00μF / 0.01μF / ± (4.0% +5)
400.0μF / 0.1μF / ± (4.0% +5)
4,000mF / 0.001mF / ± 10.0%
- overload protection at 600 Vrms

6. Temperature measurement (ranges / resolution / accuracy):

-40°C to +40°C/1°C / ±4°C
+40°C to +500°C/1°C/ ±(1.5% +5)
+500°C to +1000°C/1°C/ ±(2.0% +5)

-40°F to +104°F/1°F/ ± 6 ° F
+104°F to +932°F/1°F/ ± (2.0 +6)
+932°F to +1832°F/1°F/ ± (2.5% +4)

7. Circuit continuity check:

- if the measured resistance is less than 10Ω, the signal of the continuous circuit sounds a buzzer
- if the measured resistance is greater than 31alizace, the open circuit signal does not sound a buzzer
- open circuit voltage about 2.0V
- measurement in the range of 400Ω
- overload protection at 600 Vrms

8. Diode measurement:

- in the forward direction, the voltage drop of the semiconductor junction is less than or equal to 2V
- for a silicon junction, a typical voltage drop is 0.5 to 0.8V
- open circuit voltage about 2.2V
- measurement in the range of 4,000V


9. Contactless electric field sensing (NCV):

- allows to detect live wires in two sensitivities - EFLo and - EFHi for low voltage distribution 110V / 50 / 60Hz and 230V / 50 / 60Hz

Other parameters:

- measurement of maximum and minimum values: Yes​​
- HOLD: Yes
- low battery indication: Yes
- automatic power off: Yes
- battery supply 1.5 V (R03): 2pcs
- backlit display size: 37 mm x 25 mm
- product dimensions: 215 mm x 63 mm x 36 mm
- net weight of the product: 248 g
- product color: red and gray

Package contents:

- clamp multimeter UT202R: 1pc
- test leads: 1 pair
- battery 1.5 V (R03): 2pcs
- instructions for use: 1pc

Wholesale packaging:

- standard quantity per carton: 40pcs
- standard carton dimensions: 485 mm x 295 mm x 385 mm
- standard gross carton weight: 17.1 kg

UNI-T
UT-202R
818049934
kg
    Levertijd:1 - 2 werkdagen
Bestel